ChatterBack🔍Join
States/Connecticut/Meshtastic/WellPlacedCats
MT

WellPlacedCatsClient

!10ec7535 · WPC · TRACKER_T1000_E · Connecticut
Last heard 3 d agoBattery 79%SNR 6 dBvia meshtastic.liamcottle.net
Battery voltage
3.95 V-0.23
3.1341 readings4.19
Battery
79%-22
541 readings101
Channel busy
1.0%-1.8
1.041 readings10.1
Its own airtime
0.12%+0.07
0.0541 readings1.50
Temperature
27.7 °C-4.9
6.141 readings56.1

Channel busy is how occupied the air is where this node sits; its own airtime is how much of that this node is personally using. The second one is what tells you whether you are the congestion. Voltage is the one to watch on a solar node: a floor that drops a little further each morning is a battery on its way out, long before anything stops working.