ChatterBack🔍Join
States/Florida/Meshtastic/St cloud Roman Router 4a04
MT

St cloud Roman Router 4a04Router

!ee6f4a04 · SCRR · SEEED_SOLAR_NODE · Florida
Last heard 9 d agoBattery 97%via meshtastic.liamcottle.net
Battery voltage
4.14 V0.00
4.1455 readings4.14
Battery
97%0
9756 readings97
Its own airtime
0.75%0.00
0.7555 readings0.75

Channel busy is how occupied the air is where this node sits; its own airtime is how much of that this node is personally using. The second one is what tells you whether you are the congestion. Voltage is the one to watch on a solar node: a floor that drops a little further each morning is a battery on its way out, long before anything stops working.